Post Date : Nov 10, 2023 / Last updated : Dec 08, 2023

Manual reset function

The manual reset function of voltage detector is a function for forcibly outputting a reset signal (detection signal) even when the monitoring voltage cannot be detected.
The voltage detector is equipped with manual reset terminal. It forcibly outputs a detection signal by inputting an external signal.

“Forcible reset button” that is frequently prepared for electronic devices uses this function.
This function is sometimes used for evaluation of test production or debugging, etc. in addition to forcible reset of equipment by end user.

Example of circuit
Example of use